Overview

Structural design applies analysis results to size members in steel and reinforced concrete. The FE tests the philosophy (LRFD versus ASD), a few member-strength equations, and simple reinforced-concrete flexure and shear. Equations come from AISC and ACI; the Reference Handbook provides them, so your job is to know which one applies.

1. Design philosophies and loads

  • LRFD (load and resistance factor design): factored loads must not exceed design strength, φR_n ≥ R_u.
  • ASD (allowable strength design): unfactored loads must not exceed allowable strength, R_n/Ω ≥ R_a.

Common gravity combinations:

MethodCombination
LRFD1.4D; 1.2D + 1.6L (+ 0.5 L_r, S or R)
LRFD with roof live1.2D + 1.6(L_r or S or R) + (L or 0.5W)
LRFD wind1.2D + 1.0W + L + 0.5(L_r or S or R); 0.9D + 1.0W
ASDD + L; D + (L_r or S or R); D + 0.75L + 0.75(L_r or S or R)

Load combinations

Given: D = 40 kips, L = 60 kips.

Solution: ASD: D + L = 100 kips. LRFD: 1.2(40) + 1.6(60) = 144 kips.

2. Structural steel

Typical properties: A36 has F_y = 36 ksi; A992 wide-flange shapes have F_y = 50 ksi and F_u = 65 ksi; E = 29,000 ksi.

Tension members

Design strength is the smaller of yielding of the gross area and rupture of the net area.

φP_n = 0.90 F_y A_g (yielding), φP_n = 0.75 F_u A_e (rupture)

The net area subtracts the bolt holes (hole diameter = bolt diameter + 1/8 in): A_n = A_g − Σ(d_hole × t).

Compression members

Compute the slenderness KL/r and the elastic buckling stress:

F_e = π² E / (KL/r)²

If KL/r ≤ 4.71√(E/F_y) (about 113 for F_y = 50 ksi) the column buckles inelastically: F_cr = [0.658^(F_y/F_e)] F_y. Otherwise F_cr = 0.877 F_e. Then φP_n = 0.90 F_cr A_g.

Column strength

Given: a W-shape with A_g = 10 in², F_y = 50 ksi and KL/r = 72.

Solution: F_e = 9.87(29,000)/72² = 55.2 ksi. F_y/F_e = 0.906, so F_cr = 0.658^0.906 (50) = 34.2 ksi. φP_n = 0.90(34.2)(10) = 308 kips.

Beams

For a compact, laterally braced beam the plastic moment governs.

φM_n = 0.90 F_y Z_x

Steel beam flexure

Given: Z_x = 100 in³, F_y = 50 ksi.

Solution: M_p = 50(100) = 5,000 kip·in = 416.7 kip·ft, so φM_n = 375 kip·ft.

Lateral–torsional buckling reduces strength when the compression flange is not braced. Also check shear and deflection.

3. Reinforced concrete

Concrete is strong in compression and weak in tension; steel bars carry the tension. Properties: E_c = 57,000√f′_c (psi); a 4,000 psi concrete has E_c ≈ 3,600 ksi.

Flexure (rectangular section)

a = A_s f_y / (0.85 f′_c b), M_n = A_s f_y (d − a/2), φ = 0.90 (tension-controlled)

The reinforcement ratio is ρ = A_s/(bd). Minimum steel is the larger of 3√f′_c bd/f_y and 200bd/f_y.

Concrete beam flexure

Given: b = 12 in, d = 20 in, A_s = 3.0 in², f_y = 60 ksi, f′_c = 4 ksi.

Solution: a = 3.0(60)/[0.85(4)(12)] = 4.41 in. M_n = 3.0(60)(20 − 2.21) = 3,203 kip·in = 267 kip·ft; φM_n = 240 kip·ft.

Check: c = a/0.85 = 5.19 in and ε_t = 0.003(20 − 5.19)/5.19 = 0.0086 > 0.005, so the section is tension-controlled.

Shear

V_c = 2 √f′_c b_w d (psi, in), φ = 0.75, V_s = A_v f_yt d / s

Stirrup spacing

Given: V_u = 45 kips, b_w = 12 in, d = 20 in, f′_c = 4,000 psi, two-leg #3 stirrups (A_v = 0.22 in²), f_yt = 60 ksi.

Solution: V_c = 2√4000(12)(20) = 30.4 kips. Required V_s = 45/0.75 − 30.4 = 29.6 kips. s = 0.22(60)(20)/29.6 = 8.9 in, so use 8 in.

Detailing basics

Bar sizes: bar number = diameter in eighths of an inch (#8 = 1 in). Provide cover to protect against corrosion, enough development length for bars to reach their strength, and limit spacing for crack control.

4. Other materials

Timber design uses allowable stresses adjusted for duration, moisture and size. Masonry is strong in compression and reinforced for flexure. Connections: bolts fail in shear, bearing or tension; welds are sized by throat area.

Common mistakes

  • Using gross area where net area controls (tension with bolt holes).
  • Forgetting the strength reduction factor φ.
  • Mixing psi and ksi in the concrete shear equation.
  • Applying the elastic column formula when the column is stocky.
  • Using LRFD factors with ASD allowable strengths.

Exam strategy

Identify LRFD or ASD first, compute the demand, then compute the capacity and compare. Keep a unit table beside the equations. For columns, compute KL/r and compare it to the 113 threshold before choosing an equation.

Checklist

  • [ ] I can build LRFD and ASD load combinations.
  • [ ] I can compute tension, compression and flexural strength for steel.
  • [ ] I can find the nominal and design moment of a concrete beam.
  • [ ] I can find stirrup spacing from concrete and steel shear.
  • [ ] I know the standard material properties (A992, A36, concrete modulus).