← All topics · Civil

Hydrology & Open-Channel Hydraulics

Rational method, Manning’s equation, Froude number, weirs, runoff volume. Water Resources & Environmental depth

Rational method

Peak runoff for small catchments (< ~200 acres): Q = C i A with Q in cfs, i in in/hr, A in acres (the unit conversion is ≈ 1).

C depends on land cover (paved 0.7–0.95, lawns 0.1–0.35). The rainfall intensity i comes from the IDF curve at a duration equal to the time of concentration.

Manning's equation (US units)

V = (1.49/n) R^(2/3) S^(1/2), where R = A/P is the hydraulic radius. Q = VA.

Flow regime

Froude number Fr = V/√(g·D_h) with D_h = A/T (hydraulic depth). Fr < 1 subcritical, Fr = 1 critical, Fr > 1 supercritical.

Weirs

Sharp-crested suppressed rectangular weir: Q = 3.33 L H^(3/2) (US units, cfs).

Runoff volume

Depth × area: 1 acre-ft = 43,560 ft³. Detention storage is sized from the difference between inflow and allowable outflow hydrographs.