Overview
Environmental engineering for the FE covers water quality, treatment of drinking water and wastewater, air pollution, solid and hazardous waste, and simple mass balances. The calculations are short; the main task is remembering the treatment sequence and the correct unit conversions.
1. Water quality parameters
| Parameter | Meaning |
|---|---|
| DO | dissolved oxygen, needed by aquatic life |
| BOD | oxygen used by microbes to decompose organic matter |
| COD | oxygen needed to chemically oxidize all organics |
| pH | −log[H⁺]; neutral is 7 at 25 °C |
| Alkalinity | capacity to neutralize acid (mostly bicarbonate) |
| Hardness | Ca²⁺ and Mg²⁺, expressed as mg/L as CaCO₃ |
| Turbidity | cloudiness from suspended particles |
Hardness conversion: mg/L as CaCO₃ = mg/L ion × 50/(equivalent weight). Calcium has an equivalent weight of 20, so 80 mg/L Ca is 200 mg/L as CaCO₃.
2. BOD and oxygen demand
The oxygen demand exerted by time t follows first-order kinetics:
Five-day BOD
Given: L₀ = 300 mg/L and k = 0.23 day⁻¹ (base e).
Solution: BOD₅ = 300(1 − e^(−1.15)) = 300(1 − 0.3166) = 205 mg/L.
In a river, oxygen is consumed by decay and restored by reaeration. The dissolved oxygen sag curve reaches its minimum (the critical point) where the rate of deoxygenation equals the rate of reaeration.
3. Mass balances and reactors
For a steady state, input = output + reaction. Mixing two streams:
A completely mixed reactor (CSTR) with first-order decay k and detention time θ = V/Q has an effluent concentration:
Mixing and reactors
Mixing: a river of 10 m³/s at 2 mg/L receives 1 m³/s at 30 mg/L: C = (20 + 30)/11 = 4.5 mg/L.
CSTR: C₀ = 100 mg/L, k = 0.5 h⁻¹, θ = 2 h: C = 100/(1 + 1) = 50 mg/L.
4. Drinking water treatment
The conventional surface-water train is:
- Coagulation and flocculation: add alum or iron salts; gentle mixing builds settleable floc.
- Sedimentation: gravity settling in a basin.
- Filtration: sand or dual-media filters remove remaining particles.
- Disinfection: chlorine, chloramine, ozone or UV; effectiveness is judged by the product C·t (concentration × contact time).
Softening removes hardness with lime and soda ash. Design a settling basin with the overflow rate v₀ = Q/A and the detention time t = V/Q.
Clarifier design
Given: Q = 0.1 m³/s, surface area 50 m², volume 600 m³.
Solution: v₀ = 0.1/50 = 0.002 m/s (173 m/day). t = 600/0.1 = 6,000 s = 1.67 h.
A particle settles if its Stokes settling velocity (proportional to diameter squared) exceeds the overflow rate.
5. Wastewater treatment
- Preliminary: screens and grit removal.
- Primary: sedimentation removes settleable solids and some BOD.
- Secondary: biological treatment (activated sludge, trickling filter) removes dissolved organics.
- Tertiary: nutrient removal, filtration, disinfection.
Activated-sludge design uses two numbers:
Activated sludge
F/M: Q = 1000 m³/d, S₀ = 200 mg/L, V = 500 m³, X = 2000 mg/L gives F/M = (1000 × 200)/(500 × 2000) = 0.2 d⁻¹.
SRT: V = 1000 m³, X = 3000 mg/L, wasting 20 m³/d at 10,000 mg/L gives SRT = (1000 × 3000)/(20 × 10,000) = 15 d.
Loading in lb/day uses the conversion 8.34 × Q(MGD) × C(mg/L); 2 MGD at 20 mg/L is 334 lb/day.
6. Air pollution
Convert gas concentrations with the molar volume 24.45 L/mol (25 °C, 1 atm): mg/m³ = ppm × MW/24.45. For SO₂ (MW 64), 100 ppm is about 262 mg/m³. Control devices: cyclones and baghouses for particles, scrubbers and adsorbers for gases, and catalytic converters for exhaust.
7. Solid and hazardous waste
Modern landfills have liners, leachate collection and gas management. Hazardous waste is managed under RCRA from generation to disposal ("cradle to grave"). Waste reduction hierarchy: reduce, reuse, recycle, recover energy, then dispose.
Common mistakes
- Using base-10 and base-e rate constants interchangeably.
- Forgetting the 8.34 factor (or using it with the wrong flow unit).
- Treating hardness in mg/L of ion rather than as CaCO₃.
- Putting treatment steps in the wrong order.
- Confusing detention time with overflow rate.
Exam strategy
Memorize the treatment sequence for water and wastewater and the handful of formulas above. Write units on every term, and sketch a block diagram with arrows for flows when doing a mass balance.
Checklist
- [ ] I can compute BOD exerted and apply a mass balance.
- [ ] I can list the steps of water and wastewater treatment in order.
- [ ] I can size a clarifier with overflow rate and detention time.
- [ ] I can compute F/M, SRT and mass loading.
- [ ] I can convert ppm to mg/m³ for a gas.