← All topics · Civil

Hydrology & Hydraulics

Rational method, SCS curve number, Manning, critical depth, groundwater flow. approx. 10–15% (with Environmental)

About 4 min read · 10 sections

Overview

Hydrology estimates how much water a storm produces; hydraulics describes how it moves in pipes and channels. FE questions pair the two: compute a design flow with the rational or curve-number method, then size a channel or check a pipe. This guide follows that sequence.

1. Rainfall and runoff

Design rainfall comes from an intensity–duration–frequency (IDF) curve; the storm duration normally equals the time of concentration, the time for runoff from the most remote point to reach the outlet.

Rational method

For small catchments (under roughly 200 acres):

Q = C i A (cfs, with i in in/hr and A in acres)

C is the runoff coefficient (paved about 0.9, lawns about 0.2–0.3). For mixed land use take the area-weighted average.

Composite runoff coefficient

Given: 10 acres of pavement (C = 0.9) and 30 acres of lawn (C = 0.3), i = 3 in/hr.

Solution: C = (10 × 0.9 + 30 × 0.3)/40 = 0.45. Q = 0.45(3)(40) = 54 cfs.

SCS curve-number method

S = 1000/CN − 10, Q = (P − 0.2S)² / (P + 0.8S) (inches, valid for P > 0.2S)

Curve-number runoff

Given: CN = 80 and a 4 in storm.

Solution: S = 2.5 in and 0.2S = 0.5 in. Q = (3.5)²/(4 + 2.0) = 2.04 in of runoff.

Volume: 1 acre-ft = 43,560 ft³, so 50 acres with 2 in of runoff is 50 × 2/12 = 8.33 acre-ft.

2. Storage and routing

A detention pond reduces peak flow by storing the difference between inflow and outflow: ΔStorage = (Inflow − Outflow) × time.

Pond storage

Given: a pond receives 5 cfs and releases 3 cfs for 24 hours.

Solution: 2 cfs × 86,400 s = 172,800 ft³ = 3.97 acre-ft.

3. Open-channel flow

Manning's equation gives uniform flow velocity:

V = (1/n) R^(2/3) S^(1/2) (SI); V = (1.49/n) R^(2/3) S^(1/2) (US)

R = A/P is the hydraulic radius and Q = VA. Typical n values: smooth concrete 0.013, earth channel 0.02–0.025, natural streams 0.03–0.05.

Manning's equation

Given: a rectangular channel 2 m wide and 1 m deep, n = 0.013, S = 0.001.

Solution: A = 2 m², P = 4 m, R = 0.5 m. V = (1/0.013)(0.5)^(2/3)(0.001)^(1/2) = 1.53 m/s, so Q = 3.06 m³/s.

Specific energy and flow regime

E = y + v²/(2g)

For a rectangular channel with discharge per unit width q: critical depth y_c = (q²/g)^(1/3) and E_c = 1.5 y_c. The Froude number Fr = v/√(g y) separates subcritical (Fr < 1, deep slow flow) from supercritical (Fr > 1, shallow fast flow).

Critical depth

Given: q = 3 m²/s.

Solution: y_c = (9/9.81)^(1/3) = 0.97 m.

Hydraulic jump

Supercritical flow changing to subcritical flow produces a jump with energy loss. For a rectangular channel the sequent depth is:

y₂ = (y₁/2) [ √(1 + 8 Fr₁²) − 1 ]

Hydraulic jump

Given: y₁ = 0.5 m, v₁ = 6 m/s.

Solution: Fr₁ = 6/√(9.81 × 0.5) = 2.71. y₂ = 0.25[√(1 + 8 × 7.34) − 1] = 1.68 m.

4. Weirs and orifices

Sharp-crested rectangular weir: Q = 3.33 L H^(3/2) (US, cfs) or Q = 1.84 L H^(3/2) (SI). Orifice: Q = C_d A √(2gh). Always check that you are using the head measured above the crest or the center of the orifice.

5. Pressure pipe flow

Continuity Q = Av and the energy equation with head loss h_L govern pipe systems. Hazen–Williams (US) is common for water mains:

V = 1.318 C R^0.63 S^0.54

Hazen–Williams velocity

Given: a 1 ft diameter pipe flowing full, C = 120, S = 0.01.

Solution: R = D/4 = 0.25 ft. V = 1.318(120)(0.25)^0.63(0.01)^0.54 = 5.5 ft/s.

A pressure of 1 psi equals 2.31 ft of water, so 40 psi is 92.4 ft of head.

6. Groundwater

Darcy's law: Q = K i A, with hydraulic gradient i = Δh/L and K the hydraulic conductivity. Transmissivity T = K b for a confined aquifer of thickness b. Darcy velocity is a flux; the actual pore velocity is higher by the factor 1/n (porosity).

Common mistakes

  • Using the SI Manning equation with US numbers (1.49 versus 1.0).
  • Using the full area rather than the wetted perimeter to compute R.
  • Forgetting to convert inches to feet when finding volumes.
  • Using the rational method for watersheds that are too large.
  • Mixing up subcritical and supercritical regimes.

Exam strategy

Decide first whether the question is hydrology (flow estimate), open channel (Manning, Froude) or pipe (continuity, energy). Write the units next to each number, and compute Fr whenever depth and velocity are both known.

Checklist

  • [ ] I can estimate peak flow with the rational method and runoff with CN.
  • [ ] I can compute channel velocity and flow with Manning's equation.
  • [ ] I can find critical depth, Froude number and the sequent depth of a jump.
  • [ ] I can use weir, orifice and Hazen–Williams equations.
  • [ ] I can apply Darcy's law.